GW843682X

製品コードS2880 バッチS288001

印刷

化学情報

 Chemical Structure Synonyms Storage
(From the date of receipt)
3 years -20°C powder
1 years -80°C in solvent
化学式

C22H18F3N3O4S

分子量 477.46 CAS No. 660868-91-7
Solubility (25°C)* 体外 DMSO 95 mg/mL (198.96 mM)
Ethanol 3 mg/mL (6.28 mM)
Water Insoluble
* <1 mg/ml means slightly soluble or insoluble.
* Please note that Selleck tests the solubility of all compounds in-house, and the actual solubility may differ slightly from published values. This is normal and is due to slight batch-to-batch variations.

溶剤液(一定の濃度)を調合する

生物活性

製品説明 GW843682X is a selective, ATP-competitive inhibitor of PLK1 and PLK3, with IC50s of 2.2 nM and 9.1 nM, respectively, and is also >100-fold selective against ~30 other kinases.
in vitro

GW 843682X is a submicromolar inhibitor of proliferation of most tumor cells in culture, a notable exception being PC-3, a prostate carcinoma cell line. GW 843682X is also selective for tumor cells compared with normal diploid fibroblasts (HDF), with >10-fold difference in potency. GW 843682X is equipotent (∼200 nmol/L) against MES-SA/DX5 and the parental line MES-SA, suggesting that the compound is not effectively removed by the P-glycoprotein efflux pump in the cell. GW 843682X dose-dependently inhibits the phosphorylation of Ser15-p53 by PLK1 in HeLa cells expressing the tet-inducible chimeric p53-PLK1 protein. GW 843682X enhances HDF cell outgrowth with 30% at 3.3 μM and is able to enhance H460 outgrowth at lowest concentration of 0.37 μM. GW 843682X results in a strong G2-M arrest at 3 μM and very little G2-M arrest is observed at 1 μM in HDF cells. GW 843682X (3 μM) shows a reduced G2-M arrest, but there is an increase in sub-2N DNA content in H460 cells. GW 843682X (0.5 μM) results in cells that are larger in size than the untreated H460 cells and has multiple nuclei. [1] GW 843682X inhibits PLK1, PLK2, PLK3 and PLK4 with Ki values of 4.8 nM, 3.8 nM, 8 nM and 0.163 μM, respectively. [2] GW 843682X (1 μM) interferes with the localization of endogenous MyoGEF at the central spindle in HeLa cells. GW 843682X (1 μM) disrupts the localization of GFP-MyoGEF-wt (GFP-WT), GFP-MyoGEF-T574A (GFP-T574A), and GFP-MyoGEF-T574E (GFP-T574E) to the central spindle in HeLa cell. [3] GW-843682X causes identical premature midzone assembly and protein recruitment, suggesting that the drug effect is specific to Plk1 inhibition. GW 843682X (200 nM) causes microtubule bundling and central spindlin and PRC1 recruitments in equator in HeLa cells. [4]

プロトコル(参考用のみ)

キナーゼアッセイ In vitro Kinase Assays
PLK1 and PLK3 are added to white 384-well assay plates at variable known concentrations in 100% DMSO. DMSO (1–5% final) and EDTA (65 mM) are used as controls. Reaction Mix contains the following components at 22°C: 25 mM HEPES (pH 7.2); 15 mM MgCl2; 1 μM ATP; 0.05 μCi/well [γ-33P]ATP (10 Ci/mmol); 1 μM substrate peptide; 0.15 mg/mL bovine serum albumin; 1 mM DTT; and 2 nM PLK1 kinase domain or 5 nM full-length PLK3. Reaction Mix (10 or 20 μL) is quickly added to each well immediately following addition of enzyme via automated liquid handlers and incubated for 1 to 1.5 h at 22°C. The 20 μL enzymatic reactions are stopped with 50 μL of stop mix [50 mM EDTA, 4.0 mg/mL streptavidin SPA beads in Dulbecco
細胞アッセイ 細胞株 H460 and HDF cells
濃度 3 μM
反応時間 72 hours
実験の流れ

H460 cells are plated at a density of 2×103 per well, HDF cells are plated at 5×103 per well, and the drug-resistant cell line MES-SA/DX5 and its sensitive parent line MES-SA are plated at 7×103 and 6×103 per well, respectively, in a 96-well plate. These densities allow vehicle controls to grow logarithmically during the course of the 3-day assay. All cells are exposed to 3-fold dilutions of GW 843682X (30–0.00152 μM) in low-glucose DMEM containing 5% FBS, 50 μg/mL gentamicin, and 0.3% (v/v) DMSO (HDF cells); RPMI 1640 containing 5% FBS, 50 μg/mL gentamicin, and 0.3% (v/v) DMSO (H460); or McCoy's 5A containing 5% FBS, 50 μg/mL gentamicin, and 0.3% (v/v) DMSO (MES-SA and MES-SA/DX5).

長期の保管のために-20°Cの下で製品を保ってください。

人間や獣医の診断であるか治療的な使用のためにでない。